The short version
- Water from 360 cargo and other non-passenger ships in UK ports was tested for Legionella, and 58% of the ships were positive[1].
- The worst points were cabin showers (49% of samples positive) and the ship’s hospital shower (45%)[1].
- About 1 in 10 people who get Legionnaires’ disease die from it, and symptoms usually start 2 to 14 days after exposure[7].
- In a review of 107 studies of cruise ship outbreaks, most had low death rates, but Legionella outbreaks had a pooled case fatality of 11.4%[5].
How often ship water carries Legionella
| Study | Ships | Finding |
|---|---|---|
| UK ports, non-passenger vessels[1] | 360 ships tested for Legionella | 58% of ships positive; 27% of samples above the UK action limit; L. pneumophila serogroup 1 on 46% of ships |
| Port of Messina, Italy[4] | 10 ferries, 6 cruise ships | Serogroup 1 in shower and tap water on 7 of 10 ferries and 3 of 6 cruise ships |
| Merchant vessel off Australia, 2015[2] | 1 ship | 2 crew with Legionnaires’ disease and 1 with Pontiac fever; testing pointed to the cabins |
| Two cruise ships, 2022 to 2024[3] | 2 ships | 12 cases traced to private hot tubs on cabin balconies |
The UK study found no link between a ship’s age or size and the bacteria in its water[1]. A new or large ship is not protected by default; the water system has to be run to keep Legionella down.
Where it grows on board
| Source | Why it matters |
|---|---|
| Cabin showers | The most often positive point on non-passenger ships, 49% of samples[1]; cabins left empty let water stand[8] |
| Hospital shower | Positive in 45% of samples[1], and it is the shower used by the sickest person aboard |
| Hot tubs and whirlpool spas | The source of both 2022 to 2024 cruise outbreaks; private units were not run to public spa standards[3] |
| Technical water | Legionella has been recovered from it; deck washing creates aerosols that crew breathe[8] |
| Water left standing | Stagnation cools water into the growth range, builds biofilm and uses up disinfectant[8] |
For the drinking water rules that sit around this, see vessel potable water and sanitation rules.
The temperatures and routines that keep it down
| Control | CDC target |
|---|---|
| Hot water storage | Above 140°F (60°C)[6] |
| Hot water in circulation | Not below 120°F (49°C), recirculated continuously where possible[6] |
| Cold water | Kept below the growth range of 77 to 113°F (25 to 45°C)[6] |
| Scald protection | Thermostatic mixing valves close to the outlet, so hot water can still circulate hot[6] |
| After lay-up or low occupancy | Flush hot and cold through every outlet and bring hot water to full temperature[8] |
CDC asks cruise operators to run a written water management program covering every system that uses water, and to consider testing for Legionella to show that the program works[8]. The same logic applies to a cargo ship or workboat with cabins: a set flushing routine for outlets that go unused, including empty cabins and the hospital shower, is the cheapest control on the list[8].
When a crew member gets pneumonia at sea
- Think of it. Cough, fever and shortness of breath 2 to 14 days after exposure look like any other pneumonia[7].
- Get radio medical advice and record the cabin, the showers used and recent port calls.
- Test if the kit allows. CDC asks ship medical staff to test anyone with signs of pneumonia with a urinary antigen test[8].
- Treat as the physician directs. Legionnaires’ disease is treated with antibiotics, a macrolide or a fluoroquinolone[8]; the right antibiotics need to be in the medicine chest.
- Plan the evacuation early. A 2023 case report describes a cargo ship crew member with Legionella pneumonia who needed medical evacuation[9]; see when to medevac a seafarer.
- Report it. An illness that may be infectious belongs on the health declaration at the next port, and for US ports in the CDC report of death or illness.
One case means the water system is suspect
In both cruise outbreaks, CDC opened an investigation once a second linked case was reported[3]. After the first case on a ship, stop using the suspect shower or tub and ask for a water test before a second crew member falls ill.
Legionella on a ship is a water management problem that ends as a medical one. Discovery Health MD helps operators with both: maritime medical consulting for the water management and pneumonia protocol, ship medical chest management for the antibiotics and test kits the chest should hold, and controlled substances management for the rest of the medical stores an inspector will check. Ask a physician to review your Legionella and pneumonia plan.
Common questions
How common is Legionella on ships?
In UK port testing, 58% of 360 non-passenger ships had Legionella in their water[1].
Where is Legionella found on a ship?
Most often cabin showers and the hospital shower; on cruise ships also hot tubs[1][3].
Can you catch Legionnaires’ disease on a cruise ship?
Yes. CDC traced 12 cases on two cruise ships from 2022 to 2024 to private balcony hot tubs[3].
What water temperature controls Legionella?
CDC advises storing hot water above 60°C and keeping cold water below 25°C[6].
How deadly is Legionnaires’ disease?
About 1 in 10 people who get it die; in cruise ship outbreaks the pooled case fatality was 11.4%[7][5].
Is Legionnaires’ disease contagious between crew?
In general no; people catch it by breathing in mist that contains the bacteria[7].
How is Legionnaires’ disease treated?
With antibiotics, a macrolide or a fluoroquinolone, as the physician directs[8].